    ZEOS-AD-SHI

    Addressable combined smoke & heat detector w/ isolator

    • Supply Voltage : 17-30 V DC
    • Current – Quiescent : 450 uA max
    • Current – Device In Alarm : 4 mA – Alarm LED
    • Sensitivity: According to N54-5 or/and EN54-7
  • Incendie

    ZEOS-AD-H

    Addressable temperature/heat detector

    • Supply Voltage : 17-30 V DC
    • Current – Quiescent : 450 uA max
    • Current – Device In Alarm : 4 mA – Alarm LED
    • Sensitivity: According to N54-5 or/and EN54-7
  • Incendie

    ZEOS-AD-S

    Analogue Addressable Photoelectric Smoke Detector.

  • Incendie

    GFE-REM-IND-A

    • Supply Voltage: Loop Powered – 20V to 30V DC
    • Loop current – Remote Indicator : 0.12 mA (Quiescent) – 2.5 mA (LED ON)
    • Loop current – IO : 0.625 mA (Quiescent) – 2.5 mA (LED ON)
    • Max. Cable Size : 2.5 mm²
    • Max. Humidity : 95% RH Non-Condensin
    • Operating Temperature : -10ºC to 50ºC
    • Dim : 86(L)x86(W)x25(H)mm • Weight : 60g Boxed

  • Incendie

    GFE MCPE AI IP67

    • Operation Voltage : 20-30VDC – Current – Quiescent : 200 uA
    • Alarm : 50 mA @ 24V DC nominal • Alarm Resistance 470 Ohms max.
    • Operating Temperature : -10°C to +55°C • Storage Temperature : -30°C to +60°C
    • Colour/Case Material : Red and others / ABS & Clear/ PC – Flame Retardant 94 V0
    • Protection : IP67 – Type A – Outdoor Use
    • Max. Humidity : 95% RH Non-Condensing @ 40°C
    • Dim : 111.9(H)x111.9(W)x81.3(D)mm • Weight : 262 g includes back box and fixings
  • Incendie

    CHAMELEON MINI REP/E

    • Network Compatibility with the CHAMELEON range of control panels: G-One, GEKKO, OCTO+ and NODE+.
    • Connection to the control panels via RS422, Fibre-Optic or TCP/IP
    • Event log (10000 events)
    • Backlit graphical LCD display of 240 x 64 pixels
    • Programming by integrated keypad or Loader PC software
    • Multiple language support (menu selectable
  • Incendie

    GEKKO 2L

    • 2 loops panel
    • Supports connection to Repeaters via RS422, Fibre-Optic or TCP/IP
    • Networkable panel, compatible with OCTO+ and NODE+ range of panels
    • Up to 250 devices per loop (only 125 addresses available)
    • Up to 95 VULCAN 2 (addressable) ultra low current base sounders (32 address limit)
    • 32 individually programmable sounder addresses
    • Full Self-Addressable Devices support
    • 2 Fire output relays (change-over) and 1 Fault relay (NC – opens on fault)
    • 2 conventional alarm outputs (Individually programmable)
    • Both detection loops monitored for integrity
    • 512 fully programmable sounder and I/O groups
    • 384 fully programmable zones
    • Event log (rolling, 10000 entries)
    • Available only with ZEOS protocol
    • Compatible with all our own low cost ancillary modules
  • Incendie

    INT-TCP/IP V2

    Interface Panel to PC Software

    • supply voltage : 20 to 30V DC
    • Supply current : 28 mA
    • Configuration : Remotely via Wi-Fi, web page
    • Communication connector : Ethernet RJ45, Wi-Fi 2,4GHZ, BLE (Bluetooth Low Energy)
    • Input  : Reset as default (advanced configurations)
    • Operating temperature : -10ºC to 50ºC
    • Dimensions : 90 © x 40 (A) mm
    • Weight : 24 g
    • Compatibility : Windows XP/7/8/10, MacOS, Linux, Android, IOS
    • Panel compatibility : OCTO+, GEKKO, G-One and NODE+
    • Software compatibility : OWL and ODYSSEY (both GFE products)
  • Incendie

    ZEOS-C-SH

    MULTISENSOR SMOKE & HEAT DETECTOR

  • Incendie

    ZEOS-C-H

    Rate of Rise/Fixed Temp Heat Detector

  • Incendie

    ZEOS-C-S

    Rate of Rise/Fixed Temp Heat Detector
    Supply Voltage : 10-30 V DC
    Current – Quiescent :
    Heat: 7 uA / Smoke: 33 uA / Smoke & Heat: 35 uA
    Current – Device In Alarm : 24 mA – Alarm LEDs
    Sensitivity: According to N54-5 or/and EN54-7
    Cable Size : 0.5-2.5 mm²
    Reset/Start-Up Times : 20s max
    Colour / Case Material : White / ABS
    Max. Humidity : 95% RH Non-Condensing
    Normal / Transient Oper. Temperature :0ºC to 50ºC / -10ºC to 85ºC
    Dim : 100 mm(D)x50 mm(H)
    Weight : 92 g & 144 g inc. base
    Compatibility : ORION, ORION MINI, ORION EX, ORION-PLUS, QUAD ZMU and ZMU

  • Incendie

    VALKYRIE-IP65-CSB

    Conventional Wall Mounted – Sounder/Beacon Outdoor Use-IP65
    • Supply Voltage: 20Vto30VDC
    • Loop Current–Quiescent : 0.5 mA
    • Loop Current – Alarm Beacon : 3 mA Max.
    • Max. Cable Size : 2.5 mm²
    • Operating Temperature : -25ºC to 70ºC
    • Max. Humidity : 95% RH Non-Condensing
    • Case Material : ABS • Colour : Red
    • Protection Category: IP65 – Type B – Outdoor use
    • Dim : 112 (D) x 82 (H) mm • Weight : 205 g

  • Incendie

    ORION-MINI-REP

    Extinguishing Repeater Panel