Loading...

Global Fire

Showing 13–23 of 23 results

View :
  • Incendie

    ZEOS-C-S

    Rate of Rise/Fixed Temp Heat Detector
    Supply Voltage : 10-30 V DC
    Current – Quiescent :
    Heat: 7 uA / Smoke: 33 uA / Smoke & Heat: 35 uA
    Current – Device In Alarm : 24 mA – Alarm LEDs
    Sensitivity: According to N54-5 or/and EN54-7
    Cable Size : 0.5-2.5 mm²
    Reset/Start-Up Times : 20s max
    Colour / Case Material : White / ABS
    Max. Humidity : 95% RH Non-Condensing
    Normal / Transient Oper. Temperature :0ºC to 50ºC / -10ºC to 85ºC
    Dim : 100 mm(D)x50 mm(H)
    Weight : 92 g & 144 g inc. base
    Compatibility : ORION, ORION MINI, ORION EX, ORION-PLUS, QUAD ZMU and ZMU

  • Incendie

    VALKYRIE-IP65-CSB

    Conventional Wall Mounted – Sounder/Beacon Outdoor Use-IP65
    • Supply Voltage: 20Vto30VDC
    • Loop Current–Quiescent : 0.5 mA
    • Loop Current – Alarm Beacon : 3 mA Max.
    • Max. Cable Size : 2.5 mm²
    • Operating Temperature : -25ºC to 70ºC
    • Max. Humidity : 95% RH Non-Condensing
    • Case Material : ABS • Colour : Red
    • Protection Category: IP65 – Type B – Outdoor use
    • Dim : 112 (D) x 82 (H) mm • Weight : 205 g

  • Incendie

    ORION-MINI-REP

    Extinguishing Repeater Panel

  • Incendie

    GFE-MPX-REL-8 V2

    Orion Mul Tiplexed 8 Zone Relay Board

  • Incendie

    GFE-MPX-REL-4 V2

    Orion Mul Tiplexed 4 Zone Relay Board

  • Incendie

    GFE-REM-IND-C

    Conventional Flashing Remote Indicator

  • Incendie

    VALKYRIE-CSB-RED

    Conventional Wall Mount – Sounder/ Beacon

    • Supply Voltage: 20Vto30VDC
    • Loop Current-Quiescent: 0.5mA • Loop Current – Alarm Beacon : 3 mA Max.
    • Max. Cable Size : 2.5 mm²
    • Operating Temperature : -10ºC to 55ºC
    • Max. Humidity : 95% RH Non-Condensing
    • Case Material : ABS • Colour : Red or White
    • Protection Category : IP44 – Type A – Indoor use

     

  • Incendie

    VALKYRIE-CS-RED

    Conventional Sounder
    • Supply Voltage : 20Vto30VDC
    • Current – Sounder/ Beacon Active:10 mA-280 mW@ 28VDC
    • Maximum Sounder Output : 97 dB (@ 1 meter – 30 V DC)
    • Max. Cable Size: 2.5 mm²
    • Operating Temperature : -10ºC to 55ºC
    • Max. Humidity : 95% RH Non-Condensing
    • Case Material : ABS and PC – Colour : Red or White
    • Protection Category: IP21C – Type A – Indoor use
    • Dim :110(D)x85(H)mm • Weight: 254 g

  • Incendie

    GFE-MCPE-C

    Conventional Manual Call Point

  • Incendie

    ORION-8

    Conventional fire detection panel

  • Incendie

    ORION-4

    Conventional fire detection panel

Shopping cart

close